242
|
XC
|
403
|
406
|
10.385
|
DAID
|
Cranbrook
|
BC
|
CAN
|
na
|
DN29cq
|
400
|
1
|
|
2019-01-19
|
2024-11-17
|
1086
|
675
|
345
|
244
|
TH
|
411
|
408
|
10.3
|
DAID
|
Thompson
|
MB
|
CAN
|
na
|
EO15bt
|
1000
|
1
|
Decom Navcan phase 6 2021
|
2019-01-19
|
2021-08-08
|
2018
|
1254
|
26
|
248
|
QL
|
397
|
391
|
10.545
|
DBID
|
Lethbridge
|
AB
|
CAN
|
na
|
DN39no
|
|
1
|
Phase 9 decom 29Dec22
|
2019-01-19
|
2022-12-28
|
1039
|
646
|
357
|
251
|
YCD
|
390
|
415
|
9.998
|
DAID
|
Nanaimo
|
BC
|
CAN
|
na
|
CN89bd
|
500
|
1
|
!! Phase 11 decom Mar 21 2024 // Still transmitting on 27 Oct 2024
|
2019-01-19
|
2024-11-17
|
1352
|
840
|
320
|
257
|
XE
|
383
|
384
|
10.2
|
DAID
|
Saskatoon
|
SK
|
CAN
|
na
|
DO62oe
|
25
|
1
|
!! Phase 11 decom Nov 30 2023 // 157\' vertical
|
2019-01-19
|
2023-11-21
|
1386
|
861
|
15
|
258
|
ZSJ
|
407
|
406
|
10.162
|
DAID
|
Sandy Lake
|
ON
|
CAN
|
na
|
EO33hb
|
500
|
1
|
150' vertical
|
2019-01-19
|
2024-11-13
|
2006
|
1246
|
38
|
275
|
GEY
|
1053
|
1051
|
7.475
|
|
Greybull
|
WY
|
USA
|
na
|
DN54xm
|
50
|
1
|
ULS WRLB3034 Fast ID;'T' ant - /// GEY 275 Greybull - South Big Horn County Apt, WY, OTS to 23Dec23est:/// Decom !GEY 08/003 GEY NAV NDB DECOMMISSIONED 2208111827-PERM
|
2019-01-19
|
2022-06-02
|
579
|
360
|
33
|
284
|
QD
|
396
|
409
|
10.136
|
DAID
|
The Pas
|
MB
|
CAN
|
na
|
DO93lx
|
500
|
1
|
!! Phase 10 decom 15Jun23 // Often miskeys with the first dash in each character replaced with a dot. Sounds like AA S
|
2019-01-19
|
2023-05-19
|
1735
|
1078
|
24
|
290
|
QR
|
|
|
10.56
|
DAID
|
Regina
|
SK
|
CAN
|
na
|
DO70ri
|
100
|
1
|
!! Phase 12 decom May 16 2024 // 110\' vert
|
2019-01-19
|
2024-04-27
|
1267
|
787
|
25
|
290
|
YYF
|
390
|
405
|
10.156
|
DAID
|
Penticton
|
BC
|
CAN
|
na
|
DN09el
|
500
|
1
|
Was +1044 Hz //// Scheduled Decom with Navcan phase 8 July 14, 2022
|
2019-01-19
|
2022-06-27
|
1181
|
734
|
332
|
299
|
TV
|
402
|
411
|
10.2
|
DAID
|
Turner Valley
|
AB
|
CAN
|
na
|
DO20ts
|
200
|
1
|
QTH was listed as Turner Valley Ranch, recent listings drop the 'Ranch'. /// Decom - NavCan modernization phase 5 2021
|
2019-01-19
|
2021-02-07
|
1180
|
733
|
352
|
311
|
9Y
|
394
|
390
|
10.303
|
DAID
|
Pincher Creek
|
AB
|
CAN
|
na
|
DN39am
|
50
|
1
|
|
2019-01-19
|
2024-10-27
|
1038
|
645
|
352
|
317
|
VC
|
368
|
372
|
9.8
|
DAID
|
La Ronge
|
SK
|
CAN
|
na
|
DO75ic
|
500
|
1
|
TBD 6 Aug 21
|
2019-01-19
|
2021-08-08
|
1725
|
1072
|
14
|
326
|
DC
|
408
|
407
|
10.234
|
DAID
|
Princeton
|
BC
|
CAN
|
na
|
CN99rl
|
500
|
1
|
|
2019-01-19
|
2024-11-07
|
1218
|
757
|
329
|
332
|
VT
|
|
412
|
10.359
|
DAID
|
Buffalo Narrows
|
SK
|
CAN
|
na
|
DO55su
|
500
|
1
|
130\' vert - WWSU reports 2000W Decom - NavCan modernization phase 4
|
2019-01-19
|
2021-09-06
|
1753
|
1089
|
7
|
338
|
RYN
|
1039
|
1018
|
8.6
|
|
'Ryan' Tucson
|
AZ
|
USA
|
na
|
DM42kd
|
400
|
1
|
O/S with long term NOTAM // PRC 04/084 RYN NAV RBJ NDB U/S 240409 - 250924 // but it is on the air in Sept 2024
|
2019-01-19
|
2024-11-02
|
908
|
564
|
174
|
350
|
NY
|
392
|
407
|
9.8
|
DAID
|
Enderby
|
BC
|
CAN
|
na
|
DO00mp
|
500
|
1
|
Shown as 400W in WWSU; vertical 2011-02-19 Don Tomkinson reports, Found a spur of NY 350 at: 351.211 kHz. Fair signal, same timing and DAID. 2015-12-31 Iden Rogers reports it is mis-keying /// Decom in Feb 2021 as per Alex VE3GOP ///
|
2019-01-19
|
2021-02-22
|
1269
|
789
|
337
|
359
|
YQZ
|
400
|
399
|
10.12
|
DAID
|
Quesnel
|
BC
|
CAN
|
na
|
CO82sx
|
500
|
1
|
!! Decom NAVAIDs Modernization Program phase 3 - Mar 2020 -- Was +1015 Hz
|
2019-01-19
|
2020-03-16
|
1615
|
1003
|
334
|
362
|
RPX
|
1030
|
1020
|
8.412
|
|
Round Up
|
MT
|
USA
|
na
|
DN56rl
|
25
|
1
|
Decom .. yet active. Decom per NFDD 226 - 11 11/22/2019 -- (back on the air 02Apr2020)
|
2019-01-19
|
2023-07-31
|
748
|
465
|
21
|
365
|
AA
|
1040
|
1025
|
5.963
|
|
'Kenie' Fargo
|
MN
|
USA
|
na
|
EN17oa
|
100
|
1
|
60' 'T'; Listed in airnav as in ND, but actually just over he border in MN
|
2019-01-19
|
2024-11-13
|
1440
|
895
|
53
|
368
|
SX
|
385
|
409
|
10.307
|
DAID
|
Skookum (Cranbrook)
|
BC
|
CAN
|
na
|
DN29cw
|
500
|
1
|
|
2019-01-19
|
2024-11-07
|
1112
|
691
|
346
|
370
|
YBV
|
410
|
362
|
10.58
|
DAID
|
Berens River
|
MB
|
CAN
|
na
|
EO12li
|
25
|
1
|
Decom - NavCan modernization phase 3
|
2019-01-19
|
2021-02-22
|
1767
|
1098
|
35
|
383
|
CNP
|
1017
|
1022
|
6.46
|
|
Chappell
|
NE
|
USA
|
na
|
DN81sb
|
25
|
1
|
|
2019-01-19
|
2024-10-28
|
820
|
509
|
80
|
383
|
PI
|
1059
|
1024
|
6.003
|
|
'Tyhee' Pocatello
|
ID
|
USA
|
na
|
DN32rx
|
400
|
1
|
IDAHO NFDD 064 - 1 04/04/2022 POCATELLO TYHEE NDB IDENT PI LAT 42-57-49.5992 N LONG 112-30-58.7358 W
NAVAID STATUS SHUTDOWN ( Decom ) /// NFDD 073 - 2 04/15/2022 POCATELLO TYHEE NDB IDENT PI
LAT 42-57-49.5992 N LONG 112-30-58.7358 W NAVAID STATUS DECOMMISSIONED MODIFIED RMK DATA EFFECTIVE 19 MAY 2022
|
2019-01-19
|
2022-04-24
|
303
|
188
|
353
|
385
|
QV
|
400
|
387
|
10.46
|
DAID
|
Yorkton
|
SK
|
CAN
|
na
|
DO81rf
|
100
|
1
|
|
2019-01-19
|
2020-09-04
|
1425
|
885
|
28
|
386
|
SYF
|
1002
|
994
|
5.272
|
|
St. Francis
|
KS
|
USA
|
na
|
DM99cr
|
25
|
1
|
2016-11-15 Steve Zimmerman reports poorly formed letters. Don Ward and others have reported in past, that the YF letters are run together. /// Don T. noted back on air ( barely ) July 17, 2021 as S YF ///
|
2019-01-19
|
2021-07-16
|
882
|
548
|
90
|
388
|
MM
|
377
|
422
|
9.9
|
DAID
|
Fort Mc Murray
|
AB
|
CAN
|
na
|
DO46hp
|
125
|
1
|
(L4060/21 NOTAMR L2016/21 A) CYMM B) 2107281702 C) 2110262359 E) FORT MCMURRAY NDB MM 388KHZ U/S)* Decom May 19, 2022
|
2019-01-19
|
2020-05-24
|
1822
|
1132
|
1
|
395
|
YL
|
|
407
|
10.3
|
DAID
|
Lynn Lake
|
MB
|
CAN
|
na
|
DO96lt
|
1600
|
1
|
Decom - Navcan phase 6 2021
|
2019-01-19
|
2021-08-03
|
2006
|
1247
|
19
|
400
|
FN
|
1064
|
1025
|
6.03
|
|
'Colln' Fort Collins / Loveland
|
CO
|
USA
|
na
|
DN70mi
|
25
|
1
|
COLORADO NFDD 237 - 1 *12/13/202**1* FORT COLLINS/LOVELAND COLLN NDB IDENT FN// COLORADO NFDD 237 - 1 12/13/2021 LAT 40-21-47.4394 N LONG 104-58-16.9156 W NAVAID STATUS DECOMMISSIONED
|
2019-01-19
|
2022-06-24
|
608
|
377
|
86
|
404
|
MOG
|
1050
|
1025
|
8.031
|
|
Montague
|
CA
|
USA
|
na
|
CN81sr
|
25
|
1
|
|
2019-01-19
|
2024-11-07
|
882
|
548
|
283
|
406
|
YLJ
|
402
|
399
|
10.5
|
DAID
|
Meadow Lake
|
SK
|
CAN
|
na
|
DO54qd
|
15
|
1
|
Decom per Canadian navaid modernization plan
|
2019-01-19
|
2020-10-18
|
1565
|
972
|
8
|
413
|
YHD
|
397
|
407
|
10.5
|
DAID
|
Dryden
|
ON
|
CAN
|
na
|
EN39nu
|
250
|
1
|
200W according to WWSU; 110' vertical; Dryden Regional - Decom Navcan Phase 7
|
2019-01-19
|
2021-05-30
|
1841
|
1144
|
48
|
414
|
ATS
|
1021
|
1015
|
4.57
|
|
Artesia
|
NM
|
USA
|
na
|
DM72su
|
25
|
1
|
!ATS 10/003 ATS NAV NDB U/S 2310161355-PERM // Decom per NFDD 128 - 1 (07/06/2023)
|
2019-01-19
|
2022-03-26
|
1071
|
665
|
137
|